Dulcodes UV-Desinfektionsanlage
Page 55
ProMinent
®
Troubleshooting / Decommissioning and disposal
Red LED display is lit, “Error” appears in the display and “FAN” is flashing
Cause Fault related to fan in pump housing.
Remedy Check fan and replace if necessary.
Press the P key (reset function).
Red LED display is lit, “Error” appears in the display and “SYSTEM” is flashing
Cause Controller fault.
Remedy Disconnect the pump from the mains and reconnect.
If the error message continues, send the pump back to ProMinent.
Red LED lights up, “Error” appears in the display and “Menu” flashes.
Cause Stroke buffer full
Remedy Rectify fault
Press P key (Make a note of what effect this has on your process).
All other Errors
Please contact your ProMinent branch or representative!
Fault Signals
Yellow LED display is lit
Cause Liquid level in chemical storage tank has reached liquid level low, stage 1.
Remedy Fill chemical storage tank.
Yellow LED Display is lit and “calib” flashes
Cause The pump is calibrated and the stroke length deviates by more than ±10 % from the value at
the time of calibration.
Remedy Reset the stroke length or calibrate the pump again to the desired stroke length.
10 Decommissioning and disposal
Decommissioning
WARNING
EX-pump only: metering pumps and their periphery must be maintained or
decommissioned by qualified or authorised personnel!
For all metering pumps for metering inflammable media applies: Starting up and
emptying only supervised by a competent person.
When decommissioning the pump, ensure that all dirt and chemicals are cleaned from
the housing and particularly the liquid end.
Always take suitable precautions when using hazardous chemicals!
Ensure that the equipment is de-pressurised!
Disconnect the pump from the mains.
Empty the liquid end by placing the pump on its head and allowing the chemical to drain
out.
Rinse the liquid end with a suitable material, thoroughly rinse the liquid end after use with
hazardous materials!
If decommissioning is only temporary, maintain the correct storage conditions:
Storage temperature: -10 to +50 °C
Air humidity: < 92 % relative humidity
Disposal
WARNING
Spring under tension!
Take particular care when disassembling the pump as the return spring (Item 5, Chapter 2.2)
is under considerable mechanical tension!
IMPORTANT
Observe your locally applicable regulations (particularly with regard to electronic scrap and
gear oil)!