Vue de la page 47
Cable colour Polarity
blue -
brown +
13.9 Stroke sensor "Sigma"
Install the sensor according to the chapter "Installation, elec‐
trical".
For more information, see "Pacing relay" in the "Relay" chapter.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Data Value Unit
Nominal voltage * 8 VDC
Power consumption - active surface
uncovered
> 3 mA
Power consumption - active surface cov‐
ered
< 1 mA
Rated switching distance 1.5 mm
* Ri ~ 1 kΩ
Cable colour Polarity
blue -
brown +
13.10 Relay
The electrical data for the relay are contained in the chapter
"Installation, electrical".
13.11 Gear oil
Manufac‐
turer
Name Viscosity
class (ISO
3442)
Part no. Oil volume
Mobil Mobil Gear
634 *
VG 460 555 325 0.5 l
* or comparative gear oil
a) Pacing relay (stroke sensor with ...)
(Identity code specification "Stroke
sensor": 2)
b) Namur sensor (identity code specifica‐
tion "Stroke sensor": 3)
Technical data